logo


Effective water removal creates extra capacity in your absorber-stripper

Free or soluble water carrying over from the FCC or Coker Main Fractionator overhead systems can cause foaming problems and flooding in the Absorber-Stripper columns. Column designs that incorporate effective water removal can free-up capacity for valuable naphtha or LPG production.

The Problem
Even with bulk water removal in the overhead knockout drums or high pressure receivers, water carryover can go hand-in-hand with capacity creep. Higher charge rates can create superficial velocities that exceed design separation capabilities. Carried over free water only compounds the problem of soluble water that typically drops out of solution inconveniently in the middle of the column. Without an effective design for removal, water can cycle up in the system – condensing and re-vaporizing multiple times in the column and thus taking up valuable hydraulic capacity. Additionally, when the soluble water begins to drop out of solution, two distinct liquid phases form, and the system is susceptible to foaming. Foaming will cause poor separation of components and increase column pressure drop, hindering capacity.

The Solution
There are several conventional methods that column designers use to remove water from the Absorber-Stripper including: water draw recessed pans, water draw collector trays, and external water draw pumparounds. Water separation outside of the column (whether upstream or as a pumparound) will be covered in a future Sulzer Tower Technical Bulletin.

Water draw sumps or recessed pans are typically added to a center downcomer at the top of the Stripper or in the middle/bottom of the Absorber column, where the temperatures are cool enough to create a free water phase. In the water draw sump design, the primary separation of water from hydrocarbon must occur within the volume of the recessed pan. The small stream of water is drawn from the column and the hydrocarbon liquid overflows the sump to feed the tray below. The biggest challenge of this design is residence time. Free water droplets formed from soluble water are typically very small and require several minutes of residence time to effectively coalesce and drop out of the hydrocarbon phase. Very rarely can the volume of a sump or pan provide that amount of residence time. Additionally, when two distinct liquid phases begin to form (water drops out of solution), foaming is likely, which further complicates the ability to separate water from hydrocarbon.

Water draw collector trays can offer an order of magnitude more residence time than the recessed pan or sump design; however, a chimney tray with a lot of residence time can take up significant vertical space in a column. In a revamp design, where the column capacity has creeped over time, several methods can be used to create additional collector tray residence time. The riser and overflow duct heights can be extended to create a larger liquid volume. The downcomers from the tray above can be extended down into the liquid level on the collector so that the water can be discharged closer to the hydrocarbonwater interface, aiding in coalescence. The draw location can be located to where the liquid’s path of travel across the tray is maximized. Perforated dispersion plates can be installed in the water draw sumps to create a low turbulence zone closest to the draw so that any liquid influx does not disturb separation.

The Payout
Combined with an optimized tray or packing design, effectively removing water from the system can allow the refiner to increase FCC or Delayed Coker light product yields or charge rates. Sulzer’s retrofit water draw designs can be tailored to address the refiner’s particular constraints so that the effective removal of water can free up column hydraulic capacity for valuable hydrocarbon production.

DOWNLOAD LITERATURE

Sponsor:

Categories:

View More

  • Tray designs for extreme fouling applications

    Today refiners experience a lot of problems with processing of opportunity or heavy crudes. Such crudes have very high sulfur content and require the addition of amine scavengers before desalting. These amines decompose in the heater and create ammonium chlorides in the presence of water in the top of ...

  • Anti-fouling trays maximize coker main fractionator profitability

    The Coker Main Fractionator is systematically subjected to harsh operating conditions that can lead to deteriorating efficiency and performance due to coking and fouling. Poor reliability results in loss of profitable coking margins for the refinery. The main fractionator vapor feed from the coke drum ...

  • Improve separation in your column by increasing the number of trays

    Refiners often face revamp challenges when trying to improve separation within an existing column. Improving diesel recovery from gas oil, splitting benzene precursors from naphtha reformer charge, or simply minimizing product overlaps after capacity creep can all be difficult when limited by a fi xed ...

  • Gain 5-10% efficiency with this simple 4-pass tray revamp

    The design of 4-pass trays can be complex. It not only requires a close evaluation of the mechanical design but also the process response to that design at various flow rates. The balancing of the fluid flows across the tray can have a substantial effect on the tray performance, namely efficiency. Many ...

  • Proper design of mass transfer internals in the FCC flue gas scrubber can help reduce PM emissions

    The EPA’s New Source Performance Standards (40 C.F.R. §60.100-1-0, subpart Ja) regulates refinery particulate emissions, including the discharge of catalyst fines from the FCCU flue gas scrubber stack. Because refiners have traditionally correlated particulate matter (PM) emissions with FCCU ...

  • Improve fouling resistance in your wastewater benzene stripper

    Benzene stripper columns, built so that refineries can meet the National Emissions Standards for Hazardous Air Pollutants (NESHAP), operate with several unique conditions – low vapor rates, high liquid loads, and a high tendency toward fouling make designing well-balanced, effective internals difficult. The ...

  • Important tray design features that improve column operating reliability

    How often does Maintenance personnel open a column during a shutdown and find tray panels fallen without any obvious damage? How about tray valves stuck in the bottoms pump suction? While the initial reaction may be to blame faulty installation where the hardware was not properly tightened, the answer ...

  • Green design practices: focus on efficiency

    Green design is more than recycling scrap materials or calculating carbon footprints. It minimizes negative environmental impact through skillful design and operating practices to produce efficient, better-functioning processes. Because green practices reduce resource requirements, in many cases, they ...

  • 4 simple ways to convert turnarounds into profitable tower upgrade opportunities

    With planned outages commonly occurring at intervals of 2-5 years, a refinery turnaround is a prime opportunity to replace column and separator internals with the newest available technology. Planning for an outage with a “replacement-in-kind” strategy will address lost performance from refinery ...

  • Maximizing light cycle oil recovery in the FCC main fractionator

    Refiners operating FCCU's have adjusted their operating strategies to maximize light cycle oil production to meet the increased demand for automotive diesel. Catalyst formulations and reactor conditions can alter yields, but the refinery cannot take full advantage of the increased LCO recovery without ...

  • Responsive image Asset Management
  • Responsive image Sustainable Aviation Fuels
  • Responsive image OHL Gutermuth Butterfly valve
  • Responsive image Turnaround operations improvement
  • Responsive image Innovative Measurement Technologies
  • Responsive image The eco-friendly sulphur recovery solution
  • Responsive image Flow control solutions for refining and chemicals
  • Responsive image Best-in-Class Technology Portfolio
  • Responsive image FCC Catalyst Applications
  • Responsive image Mobile Water Solutions